<LOGO>
FM Transmitter Measurement Report
Created: 2024-05-28 14-01-45
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
100.20 MHz 3/5, 36 dBuV INTER
Pilot RDS Phase Difference
7.2 kHz -50 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
20 kHz 26 kHz 5003 0,0200
Modulation Power
Limit Measuring Tolerance
11,0 dBr 0,2 dBr
MIN AVE MAX % above 11,2 dBr
1,4 dBr 2,11 dBr 3,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" INTER " F201 0 (No PTY) 1 0 1 1 14:01, 28.05.2024
RT
"FRANCE INTER PREMIERE RADIO DE FRANCE "
AF EON
92.6, 94.6, 94.9, 99.2, 99.9, 100.2 MHz F203, F209, F222, F202
FM Scope Station: 100.20 MHz, signal: 3/5 (36 dBuV) Max at: 26 kHz MIN: 20 kHz % above 75 kHz: 0,0200 Acquired: 2024/05/28 14:00:41 Total samples: 5003 Equivalent time: 0:04:10 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: 3,9 dBr MIN: 1,4 dBr AVE: 2,11 dBr % above 11,2 dBr: 0,0 Last value: 3,0 dBr (2024/05/28 14:00:40) Station: 100.20 MHz, signal: 3/5 (36 dBuV) 13:48 13:50 13:52 13:54 13:56 13:58 14:00 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality